Sarnafil S327 Mechanically-Attached Engineered System Introduction



Download 302.19 Kb.
Page1/9
Date conversion29.04.2016
Size302.19 Kb.
  1   2   3   4   5   6   7   8   9
Sarnafil

S327 Mechanically-Attached

Engineered System
Introduction

Sarnafil S327 Mechanically-Attached Engineered System iii

System Description iii

Regional Offices iv

Part 1 – General Conditions

1.01 Description 5

1.02 Quality Assurance 5

1.03 Submittals 6

1.04 Code Requirements 6

1.05 Product Delivery, Storage and Handling 6

1.06 Job Conditions 7

1.07 Bidding Requirements 8

1.08 Warranties 9

Part 2 - Products

2.01 General 9

2.02 Membrane 9

2.03 Flashing Materials 11

2.04 Insulation/Overlayment/Recover Board 13

2.05 Attachment Components 14

2.06 Walkway Protection 15

2.07 Vapor Retarder 16

2.08 Miscellaneous Accessories 16

2.09 Sealants and Pitch Pocket Fillers 16

2.10 Miscellaneous Fasteners and Anchors 17

2.11 Related Materials 17

Part 3 – Execution

3.01 Pre-Construction Conference 17

3.02 Substrate Condition 17

3.03 Substrate Preparation 18

3.04 Substrate Inspection 21

3.05 Vapor Retarder/Air Retarder Installation 21

3.06 Wood Nailer Installation 21

3.07 Insulation Installation 22

3.08 Separation Layer Installation 22

3.09 Installation of Sarnafil Membrane 24

3.10 Hot-Air Welding of Seam Overlaps 25

3.11 Membrane Flashings 25

3.12 Metal Flashings 26

3.13 Sarnaclad Metal Base Flashings/Edge Metal 27

3.14 Edge-Tite Metal 27

3.15 Anchor-Tite Metal 27

3.16 Walkway Installation 28

3.17 Temporary Cut-Off 28

3.18 Completion 29

3.19 Details 29
INTRODUCTION TO

SARNAFIL MECHANICALLY-ATTACHED S327 ENGINEERED

Sarnafil has three Mechanically-Attached Systems, “Sarnafast®”, “Sarnafil Express” and “Sarnafil Engineered”. Each system uses polyester reinforced S327 roof membrane. S327 is available in three widths; 5-feet (5S327), 6.5-feet (6S327), and 10-feet (10S327). The membrane is fastened directly into the structural deck or the structural framing in any mechanically-attached configuration. The Engineered System is described as follows:


System Description
The Engineered System of mechanical-attachment is the most secure attachment method available. The Engineerd System uses a heavy steel bar (“Sarnabar”) that is fastened over the S327 membrane and into the roof deck or into the structural framing, effectively clamping the S327 in place. The Sarnabar is then covered with a heat-welded, narrow strip of pre-cut S327. Sarnabars are not used in the seam overlap (as done for the Sarnafast System).
The advantage of the Engineered System is that the fastening pattern, both row spacing and fastener spacing within each row, can be customized or “Engineered” for any specified wind load for that building. During periods of high wind load, the Engineered System maximizes the S327 membrane’s resistance to tearing and the fastener’s resistance to pullout and backout. The Engineered System is used on many important facilities. No other manufacturer has the experience that Sarnafil has with this attachment system.
The attached Guide Specification is generic in nature and may be amended as required to meet the project’s needs. Prior to bid, submit amended Specifications with Detail Drawings to Sarnafil’s Technical Department for review and comment.
We welcome you to review the following Guide Specifications and Detail Drawings and we ask that you contact us if you have any questions or need any additional information.
Thank you for choosing Sarnafil for your roofing and waterproofing needs.


REGIONAL OFFICES


NEW ENGLAND REGION

225 Dan Road

Canton, MA 02021

Phone:(781)821-0865

Fax:(781)821-9205

EASTERN REGION

One Park Way 3rd Floor

Upper Saddle River, NJ 07458

Phone:(201)327-0479

Fax:(201)327-4069

SOUTHERN REGION

3483 Satellite Boulevard

Duluth, GA 30096

Phone:(770)495-0025

Fax:(770)495-0027

MIDWEST REGION

20W267 101st Street, Unit E

Lemont, IL 60439

Phone:(630)739-9740

Fax:(630)739-9741


SOUTHWEST REGION

3727 Greenbriar, Suite 404

Stafford, Texas 77477

Phone: (281)325-0182

Fax: (281)325-0185

NORTHWEST REGION

505 South Broadway, Suite 110

Tacoma, WA 98402

Phone:(253)274-1500

Fax:(253)274-1501

MOUNTAIN REGION

356 Reed Avenue

Salt Lake City, Utah 84103

Phone:(801)575-8648

Fax:(801)355-4407

WESTERN REGION

10701 Holder Street

Cypress, CA 90630

Phone:(714)821-9377

Fax:(714)821-9356



CANADA

Sarnafil Ltd.

1260 Lakeshore Rd. E

Mississauga, Ontario

L5E 3B8 Canada

Phone:(905)271-7009

Fax:(905)271-6608



WEB ADDRESS:

www.sarnafilus.com




EMAIL ADDRESS:

webmaster@sarnafilus.com



SECTION 075419.07

MECHANICALLY-ATTACHED

THERMOPLASTIC MEMBRANE ROOFING

FEATURING SARNABAR IN COVERSTRIP

  1. GENERAL CONDITIONS




    1. DESCRIPTION





      1. Scope

To install a mechanically-attached Sarnafil roofing membrane with flashings and other components to comprise a roofing system.




      1. Related Work

The work includes but is not necessarily limited to the installation of:



        1. Removal of Existing Roofing and Insulation

        2. Substrate Preparation

        3. Roof Drains

        4. Vapor Retarder

        5. Wood Blocking

        6. Insulation

        7. Separation Layers

        8. Roof Membrane

        9. Fasteners

        10. Adhesive for Flashings

        11. Roof Membrane Flashings

        12. Walkways

        13. Metal Flashings

        14. Sealants





      1. Upon successful completion of work the following warranties may be obtained:



        1. Sarnafil Warranty

        2. Roofing Contractor Warranty




  1   2   3   4   5   6   7   8   9